<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
<channel>
<title>Vol. 24, No.2</title>
<link>http://tainguyenso.vnu.edu.vn/jspui/handle/123456789/104</link>
<description/>
<pubDate>Sun, 17 May 2026 14:23:08 GMT</pubDate>
<dc:date>2026-05-17T14:23:08Z</dc:date>
<item>
<title>An application of random process for controlled object identification with traffic delay problem</title>
<link>http://tainguyenso.vnu.edu.vn/jspui/handle/123456789/820</link>
<description>An application of random process for controlled object identification with traffic delay problem
Vu, Tien Viet
In the article proposed an effective method estimating transfer function model of&#13;
controlled plant including dead-time delay, based on stochatstic time series of input-output&#13;
signals. The model structure is modified with parameters optimized until the model error&#13;
becomes "white-noise" series that with inough smal auto-correlation function.
VNU Journal of Science, Mathematics - Physics. Vol. 24 (2008), No 2 (M.P), P. 101-109
</description>
<pubDate>Tue, 01 Jan 2008 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://tainguyenso.vnu.edu.vn/jspui/handle/123456789/820</guid>
<dc:date>2008-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>Thermoluminescence properties of Li2B4O7:Cu material</title>
<link>http://tainguyenso.vnu.edu.vn/jspui/handle/123456789/816</link>
<description>Thermoluminescence properties of Li2B4O7:Cu material
Ngo, Quang Thanh; Vu, Xuan Quang; Nguyen, The Khoi; Nguyen, Dac Dien
The copper-doped lithium tetraborate Li2B4O7:Cu (LBCu) is one of the famous&#13;
tissue equivalent materials for the thermoluminescent dosimetry, very useful for applications&#13;
in medical and personal dosimetry measurements. This material in powder and pellet forms&#13;
was prepared by sintering method in the Laboratory of Applied Spectroscopy and Gemology-&#13;
IMS-VAST. In this study the dosimetric characteristics of LBCu powder were examined: ho-&#13;
mogeneity of batch, reproducibility, dose response and evaluation kinetic parameters.
VNU Journal of Science, Mathematics - Physics. Vol. 24 (2008), No 2 (M.P), P. 97-100
</description>
<pubDate>Tue, 01 Jan 2008 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://tainguyenso.vnu.edu.vn/jspui/handle/123456789/816</guid>
<dc:date>2008-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>Wavelength shift in microsphere lasers</title>
<link>http://tainguyenso.vnu.edu.vn/jspui/handle/123456789/813</link>
<description>Wavelength shift in microsphere lasers
Tran, Thi Tam; Dang, Quoc Trung; Tran, Anh Vu; Le, Huu Minh; Do, Ngoc Chung
The wavelength shift effect of the Whispering Gallery Mode (WGM) laser with&#13;
Er3+/Yb3+ co-doped phosphate glass microsphere has been investigated. The experiment was&#13;
carried out by half fiber taper coupling technique. The microsphere lasers have been pumped&#13;
at 980 nm to take full advantage of energy transfer effect from ion Ytterbium to ion Erbium.&#13;
The WGM’s wavelength shift were analyzed for sphere diameters of 90 μm. The observed&#13;
lasing lines extends from 1532 nm to 1611 nm.
VNU Journal of Science, Mathematics - Physics. Vol. 24 (2008), No 2 (M.P), P. 89-96
</description>
<pubDate>Tue, 01 Jan 2008 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://tainguyenso.vnu.edu.vn/jspui/handle/123456789/813</guid>
<dc:date>2008-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>Determination of the 15 MeV bremsstrahlung spectrum from thin W target on the microtron MT-17 accelerator</title>
<link>http://tainguyenso.vnu.edu.vn/jspui/handle/123456789/810</link>
<description>Determination of the 15 MeV bremsstrahlung spectrum from thin W target on the microtron MT-17 accelerator
Pham, Duc Khue; Bui, Van Loat
Bremsstrahlung energy spectrum from thin W target produced by 15 MeV incident&#13;
electrons was determined by a combination of measurements and theoretical calculation. The&#13;
shape of spectrum was calculated by Monte-Carlo method using the code EGS4. The photon flux&#13;
measurements were performed based on the activation technique using the high pure metallic foils.&#13;
The radioactivities of the irradiated foils were measured by using a gamma spectrometer with a&#13;
high energy resolution HPGe detector. The experiments were carried out at the 15 MeV electron&#13;
Microtron MT-17 accelerator located at Institute of Physics and Electronics, Hanoi.
VNU Journal of Science, Mathematics - Physics. Vol. 24 (2008), No 2 (M.P), P. 81-87
</description>
<pubDate>Tue, 01 Jan 2008 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://tainguyenso.vnu.edu.vn/jspui/handle/123456789/810</guid>
<dc:date>2008-01-01T00:00:00Z</dc:date>
</item>
</channel>
</rss>
