Intercomparison on internal dose assessment for $^{131}I$

DSpace/Manakin Repository

Intercomparison on internal dose assessment for $^{131}I$

Show simple item record


dc.contributor.author Nguyen, Van Hung
dc.contributor.author Bui, Van Loat
dc.date.accessioned 2011-06-08T14:39:16Z
dc.date.available 2011-06-08T14:39:16Z
dc.date.issued 2009
dc.identifier.citation 179-184 vi
dc.identifier.issn 0866-8612
dc.identifier.uri http://tainguyenso.vnu.edu.vn/jspui/handle/123456789/12166
dc.description.abstract The paper resented the results of assessing internal dose for 131I by the direct method for Vietnamese objects that was issued in the Intercomparison Program of IAEA. The results on experimental measurements, calculating intake (I) of 131I to thyroid by the specilizing system for measuring thyroid activity, and committed effective dose E(50) using the specializing code of LUDEP 2.0 were shown that the results carrying out at the Nuclear Research Institute (I = 1.48.105 Bq, E (50) = 2.32 mSv) were good and were in accordance with the those of the authors in other laboratories in the world. vi
dc.language.iso en vi
dc.publisher Tạp chí Khoa học vi
dc.subject Occupational exposure, Intake, Thyroid dose, Committed effective dose, LUDEP 2.0. vi
dc.title Intercomparison on internal dose assessment for $^{131}I$ vi