DSpace
 

Tai Nguyen So - Vietnam National University, Ha Noi - VNU >
TRƯỜNG ĐẠI HỌC CÔNG NGHỆ >
PTN Micro Nano >
Articles of Universities of Vietnam from Scopus >

Search

Please use this identifier to cite or link to this item: http://tainguyenso.vnu.edu.vn/jspui/handle/123456789/12529

Title: Control of two-axis pneumatic artificial muscle manipulator with a new phase plane switching control method
Authors: Thanh T.D.C.
Ahn K.K.
Keywords: Magneto-rheological brake
Manipulator
Phase plane switching control
Pneumatic artificial muscle
Issue Date: 2007
Publisher: Journal of Mechanical Science and Technology
Citation: Volume 21, Issue 7, Page 1018-1027
Abstract: The use of robots in rehabilitation has become an issue of increasing importance because of the requirement of functional recovery therapy for limbs. A novel pneumatic artificial muscle (PAM) actuator - which has achieved increased popularity for providing safety and mobility assistance to humans performing tasks, as well as providing another advantages such as high strength and power/weight ratio, low cost, compactness, ease of maintenance, cleanliness, readily available, cheap power source, and so on - has been considered during the recent decades for use in a therapy robot, which in particular requires a high level of safety. However, some limitations still exist, such as air compressibility and the lack of damping ability of the actuator to bring the dynamic delay of the pressure response and cause the oscillatory motion. In addition, to aid rehabilitation more efficiently, the robot should adjust its impedance parameters according to the physical condition of the patient. For this purpose, the manipulator join is equipped with a Magneto-Rheological Brake (MRB). A new phase plane switching control method using MRB is proposed for tracking sinusoidal waveforms. The effectiveness of the proposed algorithm is demonstrated through an experiment using a fabricated two-axis PAM manipulator. The experiment proves that the stability of the manipulator could be greatly improved using a high gain control without regard to the change of the frequencies of the reference input and the external load condition, and without decreasing the response speed or lowering the stiffness of PAM manipulator.
URI: http://tainguyenso.vnu.edu.vn/jspui/handle/123456789/12529
ISSN: 1738494X
Appears in Collections:Articles of Universities of Vietnam from Scopus

Files in This Item:

File SizeFormat
HCM_U306.pdf47.67 kBAdobe PDFView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback